Categories

Contact Everpower

If you are interested in cooperation, please contact us immediately, we will give you feedback as soon as possible!


E-mail


25kVA Transformer for Kenya
  • 25kVA Transformer for Kenya

25kVA Transformer for Kenya


Category:

Single Phase Pole Mounted Transformers

E-mail


Technical Specification Standards And Certificates Advantages And Applications

A 25 kVA single-phase pole-mounted transformer for Kenya is designed specifically to comply with the rigorous statutory engineering requirements of the Kenya Power and Lighting Company (KPLC) and the Rural Electrification and Renewable Energy Corporation (REREC).

Because rural and peri-urban distribution grids across Kenya derive single-phase power lines directly from standard 11 kV or 33 kV three-phase medium-voltage networks, these transformers use unique step-down ratios tailored for the Kenyan grid

Technical Specification Profile (KPLC/REREC Standards)

Based on official Kenyan distribution guidelines, the 25 kVA single-phase asset profile is structured as follows: [1]

Technical Parameter 11 kV Primary System Class 33 kV Primary System Class
Rated Capacity 25 kVA (Continuous duty at 50Hz) 25 kVA (Continuous duty at 50Hz)
Primary Voltage (HV) 11,000 V (or \(11/\sqrt{3}\) kV depending on network grounding) 33,000 V (or \(33/\sqrt{3}\) kV line-to-neutral configuration)
Secondary Voltage (LV) 242 V (Single-phase standard to account for line drop) 242 V (Provides steady ~230V to consumers)
Rated Frequency 50 Hz 50 Hz
Cooling Class ONAN (Mineral oil immersed) ONAN (Mineral oil immersed)
Vector Group Ii0 or Ii6 Ii0 or Ii6
Voltage Regulation Manual de-energized tap changer (Typically ±2 × 2.5%) Manual de-energized tap changer (Typically ±2 × 2.5%)

 

 

 

IEC 60076 / BS 171

Rating:
16kva,25kVA,50kVA,100kVA,200kVA

Voltage Ratio:
6600/250V
11000/250V
33000/250V
Hz: 50

 

Hardware Profile & Anti-Vandalism Features

  • Bolt-Type Terminals: Built with high-strength, tin-plated eyebolt terminals integrated into the porcelain high-voltage and low-voltage bushings to facilitate secure mechanical connections with overhead aluminum conductors. 
  • Anti-Vandalism Protections: To comply with specific REREC Tender Specifications, the transformer design includes robust features to deter oil siphoning and core theft. This involves welded top-covers or tamper-proof cover-band bolt assemblies alongside hidden/secured oil drain valves. 
  • Protection Layout (CSP Option): Many units deployed in rural Kenya utilize the Completely Self-Protected (CSP) configuration. This setup embeds an internal secondary low-voltage circuit breaker, coordinated primary weak-link fuses, and heavy-duty external surge arresters bolted directly to the tank to handle seasonal lightning spikes

Factory Workshop

Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.

Factory
Factory
Factory

FAQ

Listed below are answers to our most commonly asked questions. Don't see your question?Contact our customer service team. We would be glad to assist you.

图片名称

Can a transformer be used outdoors?

图片名称
Yes, many transformers are designed for outdoor use, but they require waterproofing, dustproofing, and protective enclosures to withstand rain, dust, and temperature changes.
图片名称

Is transformer noise normal?

图片名称
A slight humming sound during operation is normal, caused by magnetization of the core and windings. However, if the noise is unusually loud or irregular, inspection is required.
图片名称

What causes a transformer to overheat?

图片名称
Common causes of transformer overheating include overloading, inadequate cooling, winding short circuits, or insulation aging. Prolonged overheating can shorten lifespan or cause failure.
图片名称

How often should a transformer be maintained?

图片名称
It is generally recommended to have a full inspection once a year, including insulation, cables, cooling systems, and oil quality tests to ensure safety and efficiency.
图片名称

Can a transformer run continuously?

图片名称
Yes, transformers are designed for long-term stable operation. As long as they run within rated voltage, load, and temperature limits, they can operate safely and continuously.
图片名称

What is the main function of a transformer?

图片名称
The main function of a transformer is to change voltage levels. It can step up voltage for long-distance transmission or step down voltage for safe use in equipment and households.

Send enquiry

NOTE: Please leave your email, our professionals will contact you ASAP!

图片名称

Need help with anything? Get intouch with us

Thank you for your message! Please fill out the form below, and our team will get back to you as soon as possible.

%{tishi_zhanwei}%